Technical specifications
| Measuring range – Distance |
– [Meter – Foot]
|
| Process temperature |
-50 … 200 °C [°C – °F]
|
| Process pressure |
-1 … 64 bar [Bar – kPa – psi]
|
| Version |
Cable ø 6 mm with screening tube without weight
Cable ø 6 mm with screening tube and gravity weight
Cable ø 6 mm with gravity weight
Cable ø 8 mm with abrasion protection without weight
Cable ø 8 mm with abrasion protection and gravity weight
Cable ø 8 mm with gravity weight
PA cable ø 12 mm with screening tube and gravity weight
|
| Materials, wetted parts |
PTFE
316L
PA
PEEK
Steel
|
| Threaded connection |
≥ G1, ≥ 1 NPT
|
| Flange connection |
≥ DN50, ≥ 2″
|
| Housing material |
Plastic
Aluminium
Stainless steel (precision casting)
Stainless steel (electropolished)
|
| Protection rating |
IP66/IP68 (0,2 bar)
IP66/IP67
IP66/IP68 (1 bar)
|
| Output |
Relay (DPDT)
Contactless electronic switch
Transistor (NPN/PNP)
Two-wire
|
| Ambient temperature |
-40 … 80 °C
|
Approvals
| Scope |
ATEX / Europe
CSA / Canada
FM / USA
EAC (GOST) / Belarus
EAC (GOST) / Kazakhstan
EAC (GOST) / Russia
IEC / worldwide
NEPSI / China
UKR Sepro / Ukraine
INMETRO / Brazil
CCC
|
| Explosion protection |
Intrinsic safety “i”
Dust explosion protection through housing “t”
|
| Ship approval |
ABS
BV
CCS
DNV
LR
RINA
RMROS
|
| Overfill protection |
WHG
VLAREM II
|
| SIL qualification |
SIL2
|
Display & adjustment
| Indication |
Pluggable display module PLICSLED
|





Reviews
There are no reviews yet.