VEGACAL 69

Application area

For use in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant. A full/empty adjustment is necessary for setup.
The VEGACAL 69 is a level sensor for continuous level measurement of liquids in non-conductive vessels or corrosive liquids. The double rod probe is fully insulated and highly resistant.

Your benefit

  • Low mounting expenditure through compact double rod version
  • Long service life and low maintenance due to high resistance materials
  • Maximum utilization of the vessel because measurement over the complete probe length

SKU: VEGACAL 69

Technical specifications
Measuring range – Distance
4 m [MeterFoot]

Process temperature
-50 … 100 °C [°C°F]

Process pressure
1 … 2 bar [BarkPapsi]

Version
FEP insulation

Materials, wetted parts
PTFE
PP
FEP

Flange connection
≥ DN50, ≥ 2″

Seal material
no media contact

Housing material
Plastic

Protection rating
IP66/IP67

Output
Profibus PA
Foundation Fieldbus
4 … 20 mA/HART – two-wire

Ambient temperature
-40 … 80 °C

Approvals
Scope
ATEX / Europe
EAC (GOST) / Belarus
EAC (GOST) / Kazakhstan
EAC (GOST) / Russia
IEC / worldwide
UKR Sepro / Ukraine
INMETRO / Brazil

Explosion protection
Intrinsic safety “i”

SIL qualification
SIL2

Display & adjustment
Adjustment
PLICSCOM
PC, PACTware and DTM
HART-Communicator
Software (e. g. AMS™, PDM)

Indication
Display/adjustment module PLICSCOM
VEGADIS 81
VEGADIS 82

34140-EN-Chapter-VEGACAL