Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||
|---|---|---|---|
| Measuring range |
|
||
| Process connection | threaded connection G 1/4 DN6 flat seal |
Application
| Special feature | Gold-plated contacts | ||
|---|---|---|---|
| Application | totaliser function; for industrial applications | ||
| Installation | connection to pipe by means of an adapter | ||
| Media | conductive liquids; water; hydrous media | ||
| Note on media |
|
||
| Medium temperature [°C] | 0…60 | ||
| Pressure rating [bar] | 10 | ||
| Pressure rating [Mpa] | 1 | ||
| MAWP (for applications according to CRN) [bar] | 7.3 |
Electrical data
| Operating voltage [V] | 18…30 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Inputs
| Inputs | counter reset |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 500 |
| Analogue voltage output [V] | 0…10; (scalable) |
| Min. load resistance [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
||
|---|---|---|---|
| Display range [ml/min] | -1999…3600 | ||
| Resolution [ml/min] | 1 | ||
| Set point SP [ml/min] | 20…3000 | ||
| Reset point rP [ml/min] | 5…2984 | ||
| Analogue start point ASP [ml/min] | 0…2400 | ||
| Analogue end point AEP [ml/min] | 600…3000 | ||
| Low flow cut-off LFC [ml/min] | < 60 |
Volumetric flow quantity monitoring
| Pulse value | 1…3000 ml |
|---|---|
| Pulse length [s] | 0,008…2 |
Temperature monitoring
| Measuring range [°C] | -20…80 |
|---|---|
| Resolution [°C] | 0.2 |
| Set point SP [°C] | -19.2…80 |
| Reset point rP [°C] | -19.6…79.6 |
| Analogue start point [°C] | -20…60 |
| Analogue end point [°C] | 0…80 |
| In steps of [°C] | 0.2 |
Accuracy / deviations
Flow monitoring
| Accuracy (in the measuring range) | ± (2 % MW + 0,5 % MEW) |
|---|---|
| Repeatability | ± 0,2% MEW |
Temperature monitoring
| Accuracy [K] | ± 2,5 (Q > 0,5 l/min) |
|---|
Response times
Flow monitoring
| Response time [s] | 0.15; (dAP = 0, T19) |
|---|---|
| Delay time programmable dS, dr [s] | 0…50 |
| Damping process value dAP [s] | 0…5 |
Temperature monitoring
| Dynamic response T05 / T09 [s] | T09 = 40 (Q > 1 l/min) |
|---|
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
|---|
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 | ||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 3 | ||||
| Process data binary | 2 | ||||
| Min. process cycle time [ms] | 4 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | -10…60 |
|---|---|
| Storage temperature [°C] | -25…80 |
| Protection | IP 67 |
Tests / approvals
| EMC |
|
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CPA approval |
|
||||||||||||
| Shock resistance |
|
||||||||||||
| Vibration resistance |
|
||||||||||||
| MTTF [years] | 144 | ||||||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 536.5 |
|---|---|
| Materials | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
| Process connection | threaded connection G 1/4 DN6 flat seal |
Displays / operating elements
| Display |
|
|---|
Remarks
| Remarks |
|
||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
Diagrams and graphs
|
|
|
|---|









Reviews