OGD551

  • Small compact design with standard M18 thread and PMD time-of-flight technology
  • Measurement to the nearest millimetre and monitoring of distances in the running process
  • Colour-independent range
  • Simultaneous output of distance value and reflectivity for increased process reliability

 

SKU: OGD551

$35,800.00

Product characteristics
Type of light red light
Laser protection class 1
Housing rectangular with M18 thread
Electrical data
Operating voltage [V] 18…30 DC; (“supply class 2” to cULus)
Current consumption [mA] 45; (24 V)
Protection class III
Reverse polarity protection yes
Type of light red light
Wave length [nm] 650
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs Laser On/ Off
Outputs
Total number of outputs 2
Electrical design PNP/NPN; (parameterisable)
Number of digital outputs 2
Output function 2 x normally open / normally closed; (parameterisable)
Max. current load per output [mA] 100
Number of analogue outputs 1
Analogue current output [mA] 4…20; (IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0…10; (IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Operating mode: FINE
Switching frequency DC [Hz] 20
Operating mode: STD
Switching frequency DC [Hz] 40
Operating mode: FAST
Switching frequency DC [Hz] 60
Detection zone
Max. light spot diameter [mm] 5
Light spot dimensions refer to at maximum range
Background suppression [m] < 20
Measuring/setting range
Setting range object reflectivity [%] 6…900; (reflectivity; 6 % black paper; 100 % white paper)
Operating mode: FINE
Measuring range [m] 0.05…2
Sampling rate [Hz] 60
Operating mode: STD
Measuring range [m] 0.05…2
Sampling rate [Hz] 120
Operating mode: FAST
Measuring range [m] 0.05…1
Sampling rate [Hz] 180
Software / programming
Parameter setting options Distance / reflectivity; hysteresis / window; Sensitivität; current/voltage output; Sequence modulation to avoid mutual interference by similar sensors
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1.3
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Min. process cycle time [ms] 5
IO-Link process data (cyclical)
function bit length
process value 2 x 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter; switching cycles counter
Supported DeviceIDs
Type of operation DeviceID
Default 1582
Note
For further information please see the IODD PDF file under “Downloads”
Operating conditions
Ambient temperature [°C] -25…55
Note on ambient temperature
In ambient temperatures < -10 °C a warm-up time is necessary.
Laser is off.
Storage temperature [°C] -30…80
Protection IP 65; IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 1
Notes on laser protection
Caution: laser light
laser class: 1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 258
UL approval
Ta -25…60 °C
Enclosure type Type 1
power supply Class 2
File number UL E174191
Mechanical data
Weight [g] 134.8
Housing rectangular with M18 thread
Dimensions [mm] 61.7 x 22.5 x 45.2
Thread designation M18 x 1
Materials housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
1 x alphanumeric display, 4-digit
Operating elements
3 pushbutton
Accessories
Items supplied
lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
 

a: sensor
b: object
c: background
x: distance sensor/object [mm]
y: min. distance object/background [mm]
 

1: Background any (6…90 % remission)
2: background white (90 % remission)
 

1: Background any (6…90 % remission)
2: background white (90 % remission)
 

1: Background any (6…90 % remission)
2: background white (90 % remission)
 

1: bright
2: dark
A: switch point
B: reset point
x: object brightness ( object reflectivity )
y: min. reflectivity difference to be detected safely
hysteresis curve for object reflectivity

Other data
Parameter Setting range Factory setting
SEL1 Dist / Refl Dist
OU1 Hno, Hnc, Fno, Fnc.OFF Hno
SP1 [mm] 50…2000 1000
SP1 [%] 6…900 10
nSP1 [mm] 50…2000 900
FSP1 [cm] 50…2000 1100
SF1 [mm] 10…500 50
bSP1 [%] 6…900 40
dSP1 [%] 6…900 30
SF1 [%] 1…100 10
dS1 [s] 0…0.1…5 0
dr1 [s] 0…0.1…5 0
SEL2 Dist / Refl Dist
OU2 Hno, Hnc, Fno, Fnc, OFF Hno
SP2 [cm] 50…2000 2000
SP2 [%] 6…900 6
ASP [mm] 0…2200 0
ASP [%] 0…999 0
AEP [mm] 0…2200 2000
AEP [%] 0…999 100
nSP2 [mm] 50…2000 1800
FSP2 [mm] 50…2000 2000
SF2 [mm] 10…500 50
bSP2 [%] 6…900 20
dSP2 [%] 6…900 10
SF2 [%] 1…100 10
dS2 [s] 0…0.01…5 0
dr2 [s] 0…0.01…5 0
dSO [s] 0…0.01…5 0.1
diS On / OFF On
colr rEd; GrEn; r1ou; G1ou; r2ou; G2ou; r-12; G-ou G1ou
P-n PNP,NPN PNP
OPEr (operating mode) FINE,STD, FAST FINE
SEQ auto; S1…S5 auto
The values apply at
Extraneous light on the object < 10 klx
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 15
OGD551-00_EN-US

Datasheet
EN PDF

Reviews

There are no reviews yet.

Be the first to review “OGD551”

Your email address will not be published. Required fields are marked *